1240FH-20A

Products Specifications

Features
Fast-Acting High-Current Brick Fuse, Space-Saving Surface-Mount Design, Ceramic Square Body with End Caps, Designed to Meet UL 248-1/14
Breaking Capacity @ Rated Voltage
150 A @ 250 VAC
Mounting Type
Surface Mount
Operating Temperature
-55 ℃ ~ 125 ℃
Voltage Rating
250 VAC
Ampere Rating
20 A
Typical Cold Resistance
2.9 mOhms
Typical Melting I ²t (A² Sec)
20
Size / Dimension
0.4 in x 0.13 in
Package / Case
1032 (1017 Metric)
Response Time
Fast Acting / Fast Blow

Fast Acting High Current Brick Fuse Ampere Rating 15 A - 100 A

Description

  • Fast Acting High current brick fuse
  • Surface mount deign to save space
  • Ceramic Suqare body with end cap design
  • Designed to UL248-1/14

1240FH-20A

Applications

  • Power battery protection
  • Test equipment
  • Power supplies
  • Game systems
  • Industrial equipment
  • Telecom system

Electrical Characteristics

Amp Rating % of Amp Rating Opening Time
15 A ~ 100 A 1.0 In 4 hour min.
15 A ~ 50 A 2.5 In <10s
60 A ~ 100 A 3.5 In <10s

 

Specifications

Part No. Rated Current (A) Rated Voltage ( V ) Breaking Capacity ( A )¹ Typ. Cold Resistance (mΩ)² Typical Voltage Drop ( mV ) Pre-Arcing I²t (A²sec)³
1240FH-15A 15 250 VAC
80 VDC
150 A @ 250 VAC
800 A @ 80 VDC
4.6 120 250
1240FH-20A 20 250 VAC
100 VDC
80 VDC
150 A @ 250 VAC
300 A @ 100 VDC
800 A @ 80 VDC
2.9 105 20
1240FH-25A 25 2.25 125 50
1240FH-30 30 100 VDC
80 VDC
300 A @ 100 VDC
800 A @ 80 VDC
1.5 100 90
1240FH-30AH 30 80 VDC 800 A @ 80 VDC 1.35 90 180
1240FH-40A 40 250 VAC
125 VAC
80 VDC
72 VDC
300 A @ 250 VAC
500 A @ 125 VAC
1000 A @ 80 VDC
1000 A @ 72 VDC
1.1 100 280
1240FH-50A 50 125 VAC
80 VDC
72 VDC
500 A @ 125 VAC
1000 A @ 80 VDC
1000 A @ 72 VDC
0.95 105 480
1240FH-60A 60 0.6 75 900
1240FH-80A 80 125 VAC
72 VDC
500 A @ 125 VAC
1000 A @ 72 VDC
0.44 65 1700
1240FH-100A 100 0.29 55 5000

1. AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing)
2. DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source)
3. Typical Pre-arcing I²t are measured at 10In Current, DC battery bank, but not exceeding the interrupting rating, time constant of calibrated circuit less than 50 microseconds)
4. Internal qualification for 20A - 30A @ 100VDC, UL Approval is pending
5. Internal qualification for 40A - 60A @ 80VDC, UL Approval is pending

Dimension

Unit: mm

1240FH-20A

Amp Rating L W H
15 A ~ 30 A 10.0±0.50 1.7±0.20 3.15±0.20
40 A ~ 100 A 12.30±0.40 2.70±0.20 4.50±0.20

Pad layout

1240FH-20A

1240FH-20A

1240FH-20A
1240FH-20A
15A-30A: Recommend trace thickness is 3oz; the minimum trace width is 10mm
40A-50A: Recommend trace thickness is 3oz; the minimum trace width is 15mm
60A-70A: Recommend trace thickness is 3oz; the minimum trace width is 22mm
80A-100A: Recommend trace thickness is 6oz; the minimum trace width is 33mm
Recommend stencil thickness is 0.15mm;

Packaging

  • 20A to 30A: 1500pcs fuses in tape ( width 24mm ) and reel ( dia. 13 inch );
  • 40A to 100A: 1000pcs fuses in tape ( width 24mm ) and reel ( dia. 13 inch )

Soldering Parameters

1240FH-20A

Infrared Reflow Soldering: 260 °C, 30 seconds max.

IR Reflow Profile

Preheat Heat
Temperature Min (Tsmin) 150°C
Temperature Max (Tsmax) 200°C
Time (Tsmin to Tsmax) (ts) 60 – 120 seconds
Average Ramp-up Rate (Tsmax to Tp) 3°C/second max.
Liquidous Temperature (TL) 217°C
Time at Liquidous (tL) 60 – 150 seconds
Peak Temperature (Tp) 260°C
Time within 5 °C of actual Peak Temperature (tp) 30 seconds
Average Ramp-down Rate (Tp to Tsmax) 6°C/second max.
Time 25 °C to Peak temperature 8 minutes max.

Temperature Re-rating Curve

1240FH-20A

  • Normal Operating Temperature: 25°C ± 2 °C
  • Operating Temperature: -55°C to 125°C with proper correction factor applied.
  • Chart of correction factor.

Time-Current Curves

1240FH-20A
1240FH-20A

PROSEMI TECHNOLOGY

SEND A MESSAGE

Feel free to fill out our contact form below and our support team will get back to you within 24 hours.