1240FH-20A
Products Specifications
- Features
- Fast-Acting High-Current Brick Fuse, Space-Saving Surface-Mount Design, Ceramic Square Body with End Caps, Designed to Meet UL 248-1/14
- Breaking Capacity @ Rated Voltage
- 150 A @ 250 VAC
- Mounting Type
- Surface Mount
- Operating Temperature
- -55 ℃ ~ 125 ℃
- Voltage Rating
- 250 VAC
- Ampere Rating
- 20 A
- Typical Cold Resistance
- 2.9 mOhms
- Typical Melting I ²t (A² Sec)
- 20
- Size / Dimension
- 0.4 in x 0.13 in
- Package / Case
- 1032 (1017 Metric)
- Response Time
- Fast Acting / Fast Blow
Fast Acting High Current Brick Fuse Ampere Rating 15 A - 100 A
Description
- Fast Acting High current brick fuse
- Surface mount deign to save space
- Ceramic Suqare body with end cap design
- Designed to UL248-1/14
Applications
- Power battery protection
- Test equipment
- Power supplies
- Game systems
- Industrial equipment
- Telecom system
Electrical Characteristics
| Amp Rating | % of Amp Rating | Opening Time |
|---|---|---|
| 15 A ~ 100 A | 1.0 In | 4 hour min. |
| 15 A ~ 50 A | 2.5 In | <10s |
| 60 A ~ 100 A | 3.5 In | <10s |
Specifications
| Part No. | Rated Current (A) | Rated Voltage ( V ) | Breaking Capacity ( A )¹ | Typ. Cold Resistance (mΩ)² | Typical Voltage Drop ( mV ) | Pre-Arcing I²t (A²sec)³ |
|---|---|---|---|---|---|---|
| 1240FH-15A | 15 | 250 VAC 80 VDC |
150 A @ 250 VAC 800 A @ 80 VDC |
4.6 | 120 | 250 |
| 1240FH-20A | 20 | 250 VAC 100 VDC 80 VDC |
150 A @ 250 VAC 300 A @ 100 VDC 800 A @ 80 VDC |
2.9 | 105 | 20 |
| 1240FH-25A | 25 | 2.25 | 125 | 50 | ||
| 1240FH-30 | 30 | 100 VDC 80 VDC |
300 A @ 100 VDC 800 A @ 80 VDC |
1.5 | 100 | 90 |
| 1240FH-30AH | 30 | 80 VDC | 800 A @ 80 VDC | 1.35 | 90 | 180 |
| 1240FH-40A | 40 | 250 VAC 125 VAC 80 VDC 72 VDC |
300 A @ 250 VAC 500 A @ 125 VAC 1000 A @ 80 VDC 1000 A @ 72 VDC |
1.1 | 100 | 280 |
| 1240FH-50A | 50 | 125 VAC 80 VDC 72 VDC |
500 A @ 125 VAC 1000 A @ 80 VDC 1000 A @ 72 VDC |
0.95 | 105 | 480 |
| 1240FH-60A | 60 | 0.6 | 75 | 900 | ||
| 1240FH-80A | 80 | 125 VAC 72 VDC |
500 A @ 125 VAC 1000 A @ 72 VDC |
0.44 | 65 | 1700 |
| 1240FH-100A | 100 | 0.29 | 55 | 5000 |
1. AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing)
2. DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source)
3. Typical Pre-arcing I²t are measured at 10In Current, DC battery bank, but not exceeding the interrupting rating, time constant of calibrated circuit less than 50 microseconds)
4. Internal qualification for 20A - 30A @ 100VDC, UL Approval is pending
5. Internal qualification for 40A - 60A @ 80VDC, UL Approval is pending
Dimension
Unit: mm

| Amp Rating | L | W | H |
|---|---|---|---|
| 15 A ~ 30 A | 10.0±0.50 | 1.7±0.20 | 3.15±0.20 |
| 40 A ~ 100 A | 12.30±0.40 | 2.70±0.20 | 4.50±0.20 |
Pad layout




15A-30A: Recommend trace thickness is 3oz; the minimum trace width is 10mm
40A-50A: Recommend trace thickness is 3oz; the minimum trace width is 15mm
60A-70A: Recommend trace thickness is 3oz; the minimum trace width is 22mm
80A-100A: Recommend trace thickness is 6oz; the minimum trace width is 33mm
Recommend stencil thickness is 0.15mm;
Packaging
- 20A to 30A: 1500pcs fuses in tape ( width 24mm ) and reel ( dia. 13 inch );
- 40A to 100A: 1000pcs fuses in tape ( width 24mm ) and reel ( dia. 13 inch )
Soldering Parameters

Infrared Reflow Soldering: 260 °C, 30 seconds max.
IR Reflow Profile
| Preheat Heat | |
|---|---|
| Temperature Min (Tsmin) | 150°C |
| Temperature Max (Tsmax) | 200°C |
| Time (Tsmin to Tsmax) (ts) | 60 – 120 seconds |
| Average Ramp-up Rate (Tsmax to Tp) | 3°C/second max. |
| Liquidous Temperature (TL) | 217°C |
| Time at Liquidous (tL) | 60 – 150 seconds |
| Peak Temperature (Tp) | 260°C |
| Time within 5 °C of actual Peak Temperature (tp) | 30 seconds |
| Average Ramp-down Rate (Tp to Tsmax) | 6°C/second max. |
| Time 25 °C to Peak temperature | 8 minutes max. |
Temperature Re-rating Curve

- Normal Operating Temperature: 25°C ± 2 °C
- Operating Temperature: -55°C to 125°C with proper correction factor applied.
- Chart of correction factor.
Time-Current Curves