2410LC-R500
Time Delay | 2410(6.5x1.6mm)
Brick Fuses
2410LC Series fuse for the small size and good electrical performance, reliability and quality.
Features
- Designed to UL 248-14
- Ceramic body and silver plated copper terminal
- Compatible with reflow
- Excellent environmental integrity
- One time positive disconnect
- RoHS compliant

Electrical Characteristics
| Amp Rating | % of Amp Rating | Opening Time |
|---|---|---|
| 500mA~2A | 100% | 4 Hours Min. |
| 200% | 120sec Max. |
Specifications
| Part Number |
Ampere Rating (A) |
Voltage Rating (Vac) |
Interrupting Rating |
Typical Cold Resistance (Ohms) |
Typical Melting I²t (A²Sec) |
Typical Voltage Drop (V) |
|---|---|---|---|---|---|---|
| 2410LC-R500 | 0.50 | 250 | 100A @250Vac | 0.560 | 0.053 | 0.410 |
| 2410LC-R630 | 0.63 | 250 | 100A @250Vac | 0.400 | 0.155 | 0.390 |
| 2410LC-R750 | 0.75 | 250 | 100A @250Vac | 0.299 | 0.520 | 0.380 |
| 2410LC-R800 | 0.80 | 250 | 100A @250Vac | 0.306 | 0.470 | 0.370 |
| 2410LC-1A | 1.00 | 250 | 100A @250Vac | 0.242 | 1.10 | 0.360 |
| 2410LC-1.25A | 1.25 | 250 | 100A @250Vac | 0.172 | 1.03 | 0.300 |
| 2410LC-1.6A | 1.60 | 250 | 100A @250Vac | 0.127 | 2.57 | 0.290 |
| 2410LC-2A | 2.00 | 250 | 100A @250Vac | 0.095 | 3.20 | 0.273 |
- AC Interrupting Rating (measured at designated voltage, 100% power factor)
- DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25℃
- Typical Pre-arcing I2t are measured at 10In Current
Dimension
Unit: mm/inch

Pad layout

Packaging
- Quantity: 1, 000pcs
- 12mm wide tape on 178mm(7 inch) diameter reel -specification EIA Standard 481.
Soldering Parameters

Infrared Reflow: 260°C, 30 seconds max.
IR Reflow Profile
| Parameter | |
|---|---|
| Temperature min (Tsmin) | 150 °C |
| Temperature max (Tsmax) | 200 °C |
| Time (Tsmin to Tsmax) (ts) | 60 - 120 seconds |
| Average ramp‑up rate (Tsmax to Tp) | 3 °C/second max. |
| Liquidous temperature (TL) | 217 °C |
| Time at liquidous (tL) | 60 - 150 seconds |
| Peak temperature (Tp) | 260 °C |
| Time within 5 °C of actual peak Temperature (tp) | 30 seconds |
| Average ramp‑down rate (Tp to Tsmax) | 6 °C/second max. |
| Time 25 °C to peak temperature | 8 minutes max. |
Temperature Derating Curve

Normal Operating Temperature: 23℃± 3℃
Operating Temperature: -55℃ to 125℃ with
proper correction factor applied.
Time Current Curve