PU30-400

Radial Leaded | Round/Square size
Polymer Positive Temperature Coefficient Thermistor

Features

  • Circuit Protection Low voltage over-current protection
  • Working current: 0.5A-9.0A
  • Impulse voltage: 30V
  • In line with RoHs certification, halogen-free product
  • Tinned copper clad steel wire(0.5~1.85A)/ Tinned Copper wire(2.5~9A)

 

PU30-400

Electrical Performance 

Part Number IH
(A)
I
(A)
Vmax
(V)
Imax
(A)
Time to Trip Pdtyp
(W)
R min
(Ω)
R1max
(Ω)
(A) (Sec.)
PU30-050 0.50 1.00 30 40 2.50 10.0 1.0 0.290 1.100
PU30-070 0.70 1.40 30 40 3.50 10.0 1.0 0.140 0.450
PU30-075 0.75 1.50 30 40 3.75 10.0 1.0 0.120 0.400
PU30-090 0.90 2.00 30 40 4.50 10.0 1.0 0.070 0.180
PU30-100 1.00 2.00 30 40 5.00 10.0 1.0 0.065 0.240
PU30-110 1.10 2.50 30 40 5.50 10.0 1.0 0.050 0.150
PU30-135 1.35 2.70 30 40 6.75 10.0 1.0 0.040 0.120
PU30-160 1.60 3.20 30 40 8.00 10.0 1.0 0.030 0.105
PU30-185 1.85 3.70 30 40 9.25 10.0 1.0 0.030 0.090
PU30-250 2.50 5.50 30 40 12.5 10.3 1.2 0.020 0.060
PU30-300 3.00 6.00 30 40 15.0 10.8 2.0 0.020 0.075
PU30-400 4.00 8.00 30 40 20.0 12.7 2.5 0.010 0.045
PU30-500 5.00 10.00 30 40 25.0 14.5 3.0 0.010 0.045
PU30-600 6.00 12.00 30 40 30.0 16.0 3.5 0.005 0.030
PU30-700 7.00 14.00 30 40 35.0 17.5 3.8 0.005 0.030
PU30-800 8.00 16.00 30 40 40.0 18.8 4.0 0.005 0.030
PU30-900 9.00 18.00 30 40 40.0 20.0 4.2 0.005 0.015

IH = Hold current: maximum current at which the device will not trip at 23℃ still air.
IT = Trip current: minimum current at which the device will always trip at 23℃ still air.
Vmax = Maximum continuous voltage device can withstand without damage at rated current
Imax = Maximum fault current device can withstand without damage at rated voltage.

Ttrip = Maximum time to trip(s) at assigned current.
Pdtyp =Typical power dissipation: typical amount of power dissipated by the device when in state air environment.
Rmin = Minimum resistance of device in initial (un-soldered) state.
R1max = Maximum resistance of device at 23℃ measured one hour after reflow.

Noted: All electrical function test is conducted after PCB mounted.

Thermal Derating Chart

Hold Current (A)

Part Number Ambient Operating Temperature
-40°C -20°C 0°C 23°C 40°C 50°C 60°C 70°C 85°C
PU30–050 0.725 0.650 0.575 0.500 0.420 0.380 0.350 0.305 0.250
PU30–070 1.015 0.910 0.805 0.700 0.588 0.532 0.490 0.427 0.350
PU30–075 1.088 0.975 0.863 0.750 0.630 0.570 0.525 0.458 0.375
PU30–090 1.305 1.170 1.035 0.900 0.756 0.684 0.630 0.549 0.450
PU30–100 1.450 1.300 1.150 1.000 0.840 0.760 0.700 0.610 0.500
PU30–110 1.595 1.430 1.265 1.100 0.924 0.836 0.770 0.671 0.550
PU30–135 1.958 1.755 1.553 1.350 1.134 1.026 0.945 0.824 0.675
PU30–160 2.320 2.080 1.840 1.600 1.344 1.216 1.120 0.976 0.800
PU30–185 2.683 2.405 2.128 1.850 1.554 1.406 1.295 1.129 0.925
PU30–250 3.625 3.250 2.875 2.500 2.100 1.900 1.750 1.525 1.250
PU30–300 4.350 3.900 3.450 3.000 2.520 2.228 2.100 1.830 1.500
PU30–400 5.800 5.200 4.600 4.000 3.360 3.040 2.800 2.440 2.000
PU30–500 7.250 6.500 5.750 5.000 4.200 3.800 3.500 3.050 2.500
PU30–600 8.700 7.800 6.900 6.000 5.040 4.560 4.200 3.660 3.000
PU30–700 10.15 9.100 8.050 7.000 5.580 5.320 4.900 4.270 3.500
PU30–800 11.60 10.40 9.200 8.000 6.720 6.080 5.600 4.880 4.000
PU30–900 13.05 11.70 10.35 9.000 7.560 6.840 6.300 5.490 4.500

Typical time to trip at 23˚C

A=PU30-050
B=PU30-070
C=PU30-075
D=PU30-090
E=PU30-100
F=PU30-110
G=PU30-135
H=PU30-160
I=PU30-185
J=PU30-250
K=PU30-300
L=PU30-400
M=PU30-500
N=PU30-600
O=PU30-700
P=PU30-800
Q=PU30-900

PU30-400

PU30-400

PU30-400

PU30-400

Size(mm)

Product
model
A B C D E F Lead FIG Package Qty
max max typ min max typ Φ
PU30-050 7.4 14.0 5.1 7.6 3.0 1.0 0.50 1 1000pcs
PU30-070 7.4 15.0 5.1 7.6 3.0 1.0 0.50 2 1000pcs
PU30-075 7.4 15.0 5.1 7.6 3.0 1.0 0.50 2 1000pcs
PU30-090 7.4 16.5 5.1 7.6 3.0 1.0 0.50 2 1000pcs
PU30-100 7.4 16.5 5.1 7.6 3.0 1.0 0.50 2 1000pcs
PU30-110 7.4 16.5 5.1 7.6 3.0 1.0 0.50 2 1000pcs
PU30-135 8.9 15.5 5.1 7.6 3.0 1.1 0.60 2 1000pcs
PU30-160 8.9 17.3 5.1 7.6 3.0 1.1 0.60 2 1000pcs
PU30-185 10.2 18.2 5.1 7.6 3.0 1.1 0.60 2 1000pcs
PU30-250 11.4 20.4 5.1 7.6 3.0 1.1 0.60 2 500pcs
PU30-300 11.4 17.3 5.1 7.6 3.0 1.3 0.80 3 500pcs
PU30-400 14.0 20.2 5.1 7.6 3.0 1.3 0.80 3 500pcs
PU30-500 14.0 25.0 10.2 7.6 3.0 1.3 0.80 3 300pcs
PU30-600 16.5 25.1 10.2 7.6 3.0 1.3 0.80 3 300pcs
PU30-700 19.1 27.8 10.2 7.6 3.0 1.3 0.80 3 200pcs
PU30-800 21.6 29.9 10.2 7.6 3.0 1.3 0.80 3 200pcs
PU30-900 25.5 29.9 10.2 7.6 3.0 1.3 0.80 3 100pcs

Regular Service Condition

1. Operating ambient temperature:-40℃~85℃.
2. Exceeding the applicable conditions of this product or other improper use may cause damage, or even cause electric breakdown or flame.
3. PPTC components are designed for occasional over-current in the circuit and are not recommended for continuous and continuous over current circuits.
4. Avoid contact of PPTC components with chemical solvents. Prolonged contact will damage the performance of the components.