10CT5-30A

Volts-500 DC Amps-10 to 50A
EV Fuses For New Energy Vehicles

The Prosemi EV (Electric Vehicle) fuses are made of high strength ceramic tube and high purity melt, with unique arc extinction filling  technology which is Prosemi's patent technology . The EV fuses are elaborately designed according to the actual driving status of EVs, with adherence to auto industry standards (JASO, D622/ISO8820). With high vibration durability, pefect transient current intermittent tolerance, eminent thermal shock resistance and favorable flame retardant ability,  the Prosemi fuses will provide youprotection whether the vehicle is traveling on a flat road or under a variety of harsh conditions.

Features

  • DC fuse for EV/HEV/ESS
  • Stud-mount, optional for other installation
  • Excellent DC performance
  • Design to EV fuse standard UL248-20
  • Reliability performance design refer to ISO8820-8&GB/T31465.6
  • Comply RoHS directive

10CT5-30A

Specification

Part Number Rated Current (A) Rated Voltage/
Interrupting Rating (A)
I²t (A²s)
Melting Pre-arc
Typical Cold
Resistance (moh m)
Typical Voltage
Drop (mV)
10CT5-10A 10 500Vdc/20000 130 13.5 185
10CT5-20A 20 435 5.1 145
10CT5-30A 30 1650 3.1 150
10CT5-40A 40 2850 2.2 150
10CT5-50A 50 5250 1.65 165
  • Temperature Rise :<=50K with 70% of rated current
  • Typical pre-arcing I2t measured at 10In

Part Numbering System

10CT5-30A

Dimension

Unit: mm

10CT5-xxA-E

10CT5-30A

Note: recommend tightening torque is 3.5-4.0Nm.

 10CT5-xxA-FV

10CT5-30A

10CT5-xxA-P

10CT5-30A

Average Time Current Curves

10CT5-30A

Soldering Parameter:

Wave soldering:

Solder Pot Temperature: 270°c Max. Solder Dwell Time: 10s Max.

Hand-Soldering (not recommended):

Solder Iron Temperature: 350°C+/- 5°C Heating Time: 5s Max.

Transportation and Storage

During transportation and storage, should avoid water seepage and mechanical damage.

Conditions for operation in service

Where the following conditions apply, fuses complying with this standard are deemed capable of operating satisfactorily without further qualification.
If the operating conditions exceed the following requirements, please contact manufacturer.

  • Normal temperature: -5℃ to 40℃;
  • The altitude of the site of installation of the fuses does not exceed 2 000 m above sea level;
  • The air is clean and its relative humidity does not exceed 50% at the maximum temperature of 40℃;
  • Higher relative humidities are permitted at lower temperatures, e.g. 90 % at 20℃;
  • Under these conditions, moderate condensation may occasionally occur due to variation in temperature.

Vibration

Meet JASO D622:2006 Section 6.3.3 Vibration durability test requirement, can be use on Electrical Vehicle application;

Temperature Derating Curve

Operating Temperature: -40°C to +125°C, with proper rerating factor applied.

10CT5-30A   