14CT8-70A

Vo Volts-800VDC Amps- 50 to 80A
Electric Vehicles Power Fuse

The Prosemi EV (Electric Vehicle) fuses are made of high strength ceramic tube and high purity melt, with unique arc extinction filling  technology which is Prosemi's patent technology . The EV fuses are elaborately designed according to the actual driving status of EVs, with adherence to auto industry standards (JASO, D622/ISO8820). With high vibration durability, pefect transient current intermittent tolerance, eminent thermal shock resistance and favorable flame retardant ability,  the Prosemi fuses will provide youprotection whether the vehicle is traveling on a flat road or under a variety of harsh conditions.

Features

  • Excellent DC performance
  • Stud-mount, optional for other installation
  • Designed to: UL248-20
  • Comply RoHS directive

Appications

  • DC drives Power Distribution Unit (PDU)
  • Energy storage device Inverters
  • EV&HEV Power Battery
  • EV Charging module 

Specification

Ordering P/N Rated
Current (A)
Rated Voltage/
Interrupting Rating 
I²t (A²s)
Pre-Arcing
Power Loss @ 0.5in (W)
14CT8-50A-x 50 800Vdc/50000A 2000 1.6
14CT8-60A-x 60 3600 1.65
14CT8-70A-x 70 5800 1.8
14CT8-80A-x 80 12500 2

* I2t is measured with 10In

Part Numbering System

 14CT8-70A

Dimension

14CT8-xxA-E

14CT8-70A

Note: recommend tightening torque is 4.5+/-1.0Nm.

14CT8-xxA-F

14CT8-70A

Recommended Drilling Pattern

14CT8-70A

Wave Soldering profile

14CT8-70A

Profile Feature Lead (Pb) Free Solder
Preheat Temperature min.(Tsmin) 100°C
Temperature typ.Tstyp) 120°C
Temperature max.(Tsmax) 130°C
Time (Tsmin to Tsmaxl )(ts) 70 seconds
△preheat to max Temperature 150°C max.
Peak temperature (Tp)* 250℃-260℃
Time at peak temperature (tp) 10 seconds max
5 seconds max
Ramp-down rate ~2 K/s min
~3.5 K/s typ
~5 K/s max
Time 25°C to 25°C 4 minutes

 

Average Time Current Curves

14CT8-70A

Transportation and Storage

During transportation and storage, should avoid water seepage and mechanical damage.

Conditions for operation in service

Where the following conditions apply, fuses complying with this standard are deemed capable of operating satisfactorily without further qualification.

  • Normal temperature: -5℃ to 40℃;
  • The altitude of the site of installation of the fuses does not exceed 2 000 m above sea level;
  • The air is clean and its relative humidity does not exceed 50% at the maximum temperature of 40℃;
  • Higher relative humidities are permitted at lower temperatures, e.g. 90 % at 20℃;
  • Under these conditions, moderate condensation may occasionally occur due to variation in temperature.

For operation condition other than above, please contact manufacturer.

Vibration

Meet UL248-20 Section 8.6.2.3 Vibration Test C requirement, can be use on Electrical Vehicle application;

Temperature Rerating Curve

Operating Temperature: -40°C to +125°C, with proper rerating factor applied