E2ETS-400A

DC Fuse for EV/HEV
EV Fuses

Features

  • 250Vdc ideal for EV/HEV/ESS application
  • Excellent DC performance
  • Low watts loss
  • Designed to: JASO D622 & ISO 8820-8
  • Ultra compact size
  • Stud-mount

Part Numbering System 

E2ETS-400A

Electrical Characteristics

Amp Rating(A) % of Amp Rating Opening Time
200~500A 200% 300 sec Max.
200~500A 300% 30 sec Max.
200~500A 500% 10 sec Max.

Specification

Part
Number
Rated Current
(A)
Rated Voltage
(VDC)
Interrupting
Rating
I²t (A²Sec)
Pre-arcing
Total @ 250Vdc
E2ETS-200A 200 250 50,000A 6820 18100
E2ETS-250A 250 12700 33655
E2ETS-300A 300 18500 48050
E2ETS-350A 350 28750 76180
E2ETS-400A 400 43700 124000
E2ETS-450A 450 56350 160500
E2ETS-500A 500 67600 195000
  • Temperature Rise :≤ 50K with 50% rated current

Dimension

Unit: mm

E2ETS-400A

Packaging

  • 1pcs fuse in one carton

Temperature Re-Rating Curve

E2ETS-400A

Time-Current Curve

E2ETS-400A

Transportation and Storage

During transportation and storage, should avoid water seepage and mechanical damage

Conditions for operation in service

Where the following conditions apply, fuses complying with this standard are deemed capable of operating satisfactorily without further qualification; Normal temperature: -5℃ to 40℃; The altitude of the site of installation of the fuses does not exceed 2 000 m above sea level; The air is clean and its relative humidity does not exceed 50 % at the maximum temperature of 40℃; Higher relative humidities are permitted at lower temperatures, e.g. 90 % at 20℃; Under these conditions, moderate condensation may occasionally occur due to variation in temperature. For operation condition other than above, please contact manufacturer.

Vibration

Meet JASO D622:2006 Section 6.3.3 Vibration durability test requirement, can be use on Electrical Vehicle application;