H10SA-175A-TA
Features
- Fast Acting fuse for DC Application
- 1000Vdc ideal for EV or HEV application
- Stud-mount, optional for other installation
- Reliability performance design refer to ISO8820-8&GB/T31465.6
- Excellent DC performance
- Design to EV fuse standard UL248-20
- Comply RoHS directive
Specifications
Part Number |
Rated Current (A) | Rated Voltage (Vdc) | Breaking Capacity (A) | I2t (A2S) Pre-arc Total @1000Vdc | Power Loss (W) | |
H10SA-63A-TA | 63 | 1000 | 50000 | 930 | 4650 | 13.9 |
H10SA-80A-TA | 80 | 1000 | 50000 | 1580 | 8100 | 15.8 |
H10SA-100A-TA | 100 | 1000 | 50000 | 2545 | 12500 | 20.8 |
H10SA-125A-TA | 125 | 1000 | 50000 | 4520 | 22000 | 25.5 |
H10SA-150A-TA | 150 | 1000 | 50000 | 6320 | 34500 | 31.5 |
H10SA-160A-TA | 160 | 1000 | 50000 | 7330 | 39800 | 34.5 |
H10SA-175A-TA | 175 | 1000 | 50000 | 10550 | 55900 | 34.6 |
Dimension (mm)
Note: Recommend tightening torque is 12+/-1.0Nm (M8)
Temperature Re-Rating Curve
Time-Current Curve
Transportation and Storage
During transportation and storage, should avoid water seepage and mechanical damage.
Conditions for operation in service
Where the following conditions apply, fuses complying with this standard are deemed capable of operating satisfactorily without further qualification;
Normal temperature: -5℃ to 40℃;
The altitude of the site of installation of the fuses does not exceed 2 000 m above sea level;
The air is clean and its relative humidity does not exceed 50 % at the maximum temperature of 40℃;
Higher relative humidities are permitted at lower temperatures, e.g. 90 % at 20℃;
Under these conditions, moderate condensation may occasionally occur due to variation in temperature.
For operation condition other than above, please contact manufacturer.
Vibration
Meet UL248-20 Section 8.6.2.3Vibration Test C requirement, can be use on Electrical Vehicle application.